Product Detail

APC APDU9959EU3 power distribution unit (PDU) 24 AC outlet(s) 0U Black



Mfr Part Number: APDU9959EU3
Manufacturer: APC
Model: APDU9959EU3
EAN: 0731304356295

Unit Price: Log in for Prices

Availability: 32 In Stock
Condition: New


Product Description

NetShelter Switched Rack PDUs Features & Benefits
Manageability

1% Metering Accuracy
Providing the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use these PDUs to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Available on 9000 series PDUs.
Gigabit Ethernet Connectivity
9000 series PDUs provide Gigabit Ethernet to enhance and standardize network connectivity across all assets in the data center. All other models provide 10/100 ethernet connectivity.
Network Port Sharing
Connect and manage multiple PDUs from one IP address to simplify and speed deployment while saving the cost required in having a dedicated network connection for each PDU. Manage up to 32 PDUs with 9000 series and up to 4 PDUs with 8000 series.
Multi-tier user access
Supports up to four access levels - Administrator, Device User, Read-Only User and Network-only User - with user name and password requirements.
Outlet Level Grouping
Outlet power sequencing can be configured to group any combination of outlets to power up or down together providing flexibility.
EcoStruxure IT Ready
Seamless integration of one or many PDUs including alerts and control with EcoStruxure IT. Allows IT and data center professionals to monitor and manage all of their critical IT infrastructure on-premise, in the cloud, and at the edge from anywhere.
Enhanced Cybersecurity
9000 series PDUs include APC Network Management card with security features including secured interfaces and a modified password policy providing peace of mind.
Network Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Adaptability
Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 17.3kW using a single branch whip.

Agility
Wireless Connectivity
Compatible with the optional APC USB WiFi Device for cableless connectivity over WiFi that speeds deployment and simplifies moves, adds, and changes (9000 Series PDUs only - expected to be available on units manufactured after March 2021).
Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

Availability
60C Operating Temperature
Select 9000 series PDUs provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today's high density deployments. Other models allow up to 45C (113F).
Hydraulic Magnetic Circuit Breakers
Provide increased availability by maintaining trip current over a wide temperature range.
C13/C15 and C19/C21 Hybrid Outlets
Available on select 9000 series PDUs only, Industry 1st hybrid outlets allow 60C operating temperature at full load, are fully compatible with standard C14 and C20 power cords, and are future proofed for implementation of higher temperature rated devices requiring C16 and C21 power cords.
High Retention Outlets
With no special power cords required, high retention outlets provide up to twice the holding force to reduce risk of accidental disconnect on 9000 series PDUs.
Field-replaceable NMC
Integrated Network Management Card/Display Module can be replaced in the field to minimize downtime disruption in the unlikely event of a failure.

Warranty: 3 years repair or replace

Manufacturers Product Link: https://www.apc.com/shop/in/en/products/APC-Rack-PDU-9000-Switched-ZeroU-16A-230V-21-C13-3-C19-IEC309-Cord/P-APDU9959EU3

Technical Specification

Design

PDU types Switched
Type Single-phase
Rack capacity 0U
Mounting Vertical
Product colour Black
Display LCD
On/off switch No

Ports & interfaces

AC outlets quantity 24 AC outlet(s)
Power plug IEC 60309
AC outlet types C13 coupler, C19 coupler

Features

Daisy chain Yes
Cable length 3 m
Certification EAC, EN 55022 class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC part 15 class A, ICES-003, RCM, VDE

Power

Nominal input voltage 230, 220 - 240 V
AC input frequency 50 - 60 Hz
Maximum current 16 A
Nominal output voltage 239 V
Output voltage 230 V
Load capacity 3680 VA
Maximum input current per phase 16 A
Maximum total current draw per phase 16 A
Maximum power 3680 W

Weight & dimensions

Width 55 mm
Depth 46 mm
Height 1794 mm
Weight 5.61 kg

Packaging data

Package weight 8.59 kg
Package width 165 mm
Package depth 114 mm
Package height 2002 mm

Operational conditions

Operating temperature (T-T) -5 - 45 °C
Storage temperature (T-T) -25 - 65 °C
Operating relative humidity (H-H) 0 - 95%
Storage relative humidity (H-H) 5 - 95%
Operating altitude 0 - 3048 m
Non-operating altitude 0 - 15240 m